Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
Fluke 810 Vibration Tester best solution when you need an answer now! not only this vibration tester has some great features but also the value of the result always spot on.
With the Fluke 810 Vibration Tester most advanced troubleshooting tool for mechanical maintenance, you can do your work simple step-by-step process to report on specific machine faults. Also their severity the first time measurements are taken, without prior measurement history.
So, now we surely say that Fluke 810 Vibration Tester is the best option for overall vibration measurements and spectral diagrams give engineers the ability to quickly asses overall machine health. While enhanced reporting and actionable recommendations give you the confidence you need to address critical problems first.
You can use the Fluke 810 Vibration Tester to:
As a Fluke distributor in Bangladesh, we think about our customer's value. Our customers are the main focal point for us. We always try to support our customers in any situation.
Diagnostic Specifications | ||
---|---|---|
Standard Faults | Unbalance, looseness, misalignment and bearing failures | |
Analysis For | Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles | |
Motor Rotational Speed Range | 200 rpm to 12000 rpm | |
Diagnosis Details | Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra |
Electrical Specifications | ||
---|---|---|
Ranging | Automatic | |
A/D Converter | 4 channel, 24 bit | |
Usable Bandwidth | 2 Hz to 20 kHz | |
Sampling | 51.2 Hz | |
Digital Signal Processing Functions | Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging | |
Sampling Rate | 2.5 kHz to 50 kHz | |
Dynamic Range | 128 dB | |
Signal To Noise Ratio | 100 dB | |
FFT Resolution | 800 lines | |
Spectral Windows | Hanning | |
Frequency Units | Hz, orders, cpm | |
Amplitude Units | in/sec, mm/sec, VdB (US), VdB* (Europe) | |
Non-volatile Memory | SD micro memory card, 2 GB internal + user accessible slot for additional storage |
General Specifications | ||
---|---|---|
Dimensions (H x D x W) | 18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52 in) | |
Weight (With Battery) | 1.9 kg (4.2 lb) | |
Display | ¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight | |
Input/Output Connections | Triaxial sensor connection | 4 pin M12 connector |
Single axis sensor connection | BNC connector | |
Tachometer Connection | Mini DIN 6 pin connector | |
PC Connection | Mini ‘B’ USB (2.0) connector | |
Battery | Battery type | Lithium-ion, 14.8 V, 2.55 Ah |
Battery charging time | Three hours | |
Battery discharge time | Eight hours (under normal conditions) | |
AC Adapter | Input voltage | 100 VAC to 240 VAC |
Input frequency | 50/60 Hz | |
Operating System | WinCE 6.0 Core | |
Language Support | English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish | |
Warranty | Three-years |
Environmental Specifications | ||
---|---|---|
Operating Temperature | 0°C to 50°C (32°F to 122°F) | |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) | |
Operating Humidity | 10% to 95% RH (non-condensing) | |
Agency Approvals | CHINA RoHS, CSA, CE, C TICK, WEEE | |
Electromagnetic Compatibility | EN 61326-1:2006, EN 61010:1:2001 2nd ed. |
Sensor Specifications | ||
---|---|---|
Sensor Type | Accelerometer | |
Sensitivity | 100 mV/g (±5%, 25°C) | |
Acceleration Range | 80 g peak | |
Amplitude Nonlinearity | 1% | |
Frequency Response | Z | 2 - 7,000 Hz ±3dB |
X, Y | 2 - 5,000 Hz ±3dB | |
Power Requirement (IEPE) | 18 VDC to 30 VDC, 2 mA to 10 mA | |
Bias Output Voltage | 12 VDC | |
Grounding | Case grounded | |
Sensing Element Design | PZT ceramic / shear | |
Case Material | 316L stainless steel | |
Mounting | 10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength) | |
Output Connector | 4-Pin, M12 | |
Mating Connector | M12 - F4D | |
Non-volatile Memory | TEDS 1451.4 compatible | |
Vibration Limit | 500 g peak | |
Shock Limit | 5000 g peak | |
Electromagnetic Sensitivity, Equivalent g | 100 μg/gauss | |
Sealing | Hermetic | |
Temperature Range | -50°C to 120°C (-58°F to 248°F) ±7% | |
Warranty | One-year |
Tachometer Specifications | ||
---|---|---|
Dimensions (D x W) | 2.86 x 12.19 cm (1.125 x 4.80 in) | |
Weight | 96 g (3.4 oz) with cable | |
Power | Powered by 810 Vibration Tester | |
Detection | Laser Diode Class 2 | |
Range | 6.0 to 99,999 rpm | |
Accuracy | 6.0 to 5999.9 rpm | ±0.01% and ±1 digit |
5999.9 to 99999 rpm | ±0.05% and ±1 digit | |
Resolution | 0.1 rpm | |
Effective Range | 1 cm to 100 cm (0.4 in to 39.27 in) | |
Response Time | 1 second (> 60 rpm) | |
Controls | Measure on/off transparent button | |
Interface | 6 Pin Mini DIN | |
Cable Length | 50 cm (19.586 in) | |
Warranty | One-year | |
Tachometer Accessories | Reflective tape | 1.5 x 52.5 cm (0.59 x 20.67 in) |
Viewer PC Software | ||
---|---|---|
Minimum Hardware Requirements | 1 GB RAM | |
Operating System Requirements | Windows 7, 8.1, and 10 |