Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
The Fluke 376 True-RMS Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians for the measurement in single phase and three phase conductors. This digital multimeter measures current, voltage, resistance, frequency, capacitance and so on without disturbance in a high electromagnetic field.
The 376 FC clamp meter uses integrated low-pass filters to measure non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp meter also uses unique inertial measurement technology to filter the noise and capture the motor flowing motor just as the circuit protection shows.
Measure:
The 376 clamp meter carries a CAT III 1000V, CAT IV 600V protection rating designed to give you the highest potential protection on a piece of test tools.
The included iFlex flexible current probe provides easy access to large conductors in tight spaces. Flexible investigation:
The measurement range extends to 2500A at alternating current(Ac).
We offer Fluke 376 clamp meter at the best price in BD. The most important thing that we provide free delivery of any place in Bangladesh.
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
|||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||
376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
|||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1% ± 5 digits | |||
mV dc | ||||
Range | 375 and 376 | 500.0 mV | ||
Resolution | 0.1 mV | |||
Accuracy | 1% ± 5 digits | |||
Frequency via Jaw | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥10 A | |||
10 – 100 Hz, ≥5 A | ||||
100 – 500 Hz, ≥10 A | ||||
Frequency via Flexible Current Probe | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
20 – 100 Hz, ≥ 20 A | ||||
100 – 500 Hz, ≥ 25 A | ||||
Resistance | ||||
Range | 374 375 and 376 |
6000 Ω 60 kΩ |
||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
||
375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
|||
Accuracy | 1% ± 5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
|||
Accuracy | 1% ± 4 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
Weight | 388 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | 10°C – +50°C | |||
Storage Temp | -40°C – +60°C | |||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
|||
Operating Altitude | 3000 meters | |||
Storage Altitude | 12,000 meters | |||
EMC | EN 61326-1:2006 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
|||
Safety Specifications | ||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
|||
Agency Approvals | ||||
Batteries | 2 AA, NEDA 15A, IEC LR6 |