Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
Amprobe UAT-620 Underground Utilities Locator Kit is rugged reliable that Accidentally hitting a facilitate stock during a project can benefit to costly repairs and make hazardous public safety situations. Digging in the wrong place can moreover gain unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption gone the rugged and durable Amprobe UAT-600 Series, meant to adroitly pinpoint underground utilities and buried services taking place to 100 feet deep gone accurate severity measurement to 20 feet.
The locating kit comes colossal and ready for use past a Transmitter, Receiver, exam benefit kit, batteries, and auxiliary fuses, all in a mobile, protective duffle sack. The UAT-620 kit as well as includes a Signal Clamp for transmitting a signal once it is not reachable to make an electrical break following the cable to be traced. For applications where arena anomaly locating is required, use the UAT-600 Transmitter in the act once the optional A-Frame add occurring.
Main applications
Locate energized 50/60 Hz cables carrying current
Identify the location of all metallic utilities: pipes*, energized and de-energized cables
Trace individual pipes* or cables (energized or de-energized)
*Tracing of non-metallic pipes and conduits is possible after inserting metal fish stamp album or cable
Three testing modes for a broad range of applications
Passive knack mode (50/60 Hz) tracing energized lines conducting current (no Transmitter necessary)
Passive radio mode (RF) using surrounding radio waves to smack underground utilities (no Transmitter injured)
Active mode using UAT-600-T Transmitter
Three nimble modes using the UAT-600-T Transmitter
Induction the Transmitter will automatically begin to radiate a signal on it using an internal antenna, used for tracing individual cables where there is no entry to the stock to join exam leads or a clamp
Direct association once test leads the most obedient method to relish individual cable or a pipe
Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) provides an efficient and safe method of applying a sit in judgment signal to a cable, where it is not practicable/attach to profit entry to a cable for making an electrical door
Special applications
2 frequency options: 8 kHz and 33 kHz
Locate non-metallic pipes and sewer lines
Take severity and current measurements
Measure voltage, resistance and output current
Advanced locating following two people
Locate showground faults gone the optional AF-600 A-Frame optional add-on
Unparalleled safety
Stop compromising become primeval and safety. What in reality sets the UAT-600 Series apart from subsidiary underground locators is its CAT IV 600 V safety rating. This allows you to safely connect going on the Transmitter directly to an energized lineage happening to 600 V in a CAT IV environment. Previously, if a crew needed to reference a specific electrical descent by transmitting a signal through it, the origin had to be de-energized first, accumulation era and reducing productivity.
Features | UAT-600-R Receiver | UAT-600-T Transmitter | SC-600 Signal Clamp (included with UAT-620, optional for UAT-610) |
Measurement category | CAT IV 600 V | ||
Operating voltage/current | 0 to 600 V | 0 to 600 V, 100 A max. | |
Operating frequency/tracing modes | Active tracing: 33 kHz and 8 kHz Passive tracing: 50/60 Hz and Radio |
Energized circuit Induction mode: 33 kHz Direct connection modes: 8 kHz and 33 kHz Clamp mode: 8 kHz and 33 kHz De-Energized circuit Induction mode: 33 kHz Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi A-Frame: 8 kHz Clamp mode: 8 kHz and 33 kHz |
33 kHz and 8 kHz |
Locating modes | Peak and Null | – | – |
Depth measurement and accuracy | Up to 20 ft 4 in to 10 ft: pm; 3 % 10 ft to 20 ft: pm; 5 % |
– | – |
Display backlight | Automatic | Yes | – |
Audio indication | Increasing closer to the signal | Fast beeps showing the better signal is applied | – |
Transmitting mode power output | – | Max. 3 watts | – |
Output voltage | – | Max. 50 V rms | – |
Output current | – | Max. 250 mA rms, constant current in 5 steps | – |
Signal voltage output (nominal) | – | – | 23 V rms at 8 kHz 30 V rms at 33 kHz |
Mains voltage measurement | – | 0 V to 600 V, 50 Hz to 60 Hz Resolution: 1 V Accuracy: pm; 10% |
– |
Resistance measurement (De-energized circuit) |
– | 0 ohm; to 999 k ohm; Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;) Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;) Accuracy: pm; 10% |
– |
Output hazardous voltage warning | – | ≥ 30 V rms | – |
Mains hazardous voltage warning | – | ≥ 30 V rms | – |
Sensitivity adjustment (gain control) | Yes | – | – |
Sensitivity at 1 m (typical) | Power: 2 mA Radio: 20 μA 8 kHz: 5 μA 33 kHz: 5 μA |
– | – |
Display | 4.3 in, 320 x 240 BW outdoor LCD display with auto backlight | LCD display (LED backlight) 2.4 in x 1.3 in |
– |
Update rate | Instantaneous | Current (mA): 10 ms Voltage (V): 15 ms Resistance ( ohm;): 330 ms |
– |
Operating temperature and humidity | -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH | ||
Storage temperature and humidity | -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH | ||
Operating altitude | < 6561 ft (< 2000 m) | ||
Pollution degree | 2 | ||
Water and dust resistance | IP54 | ||
Drop proof | 3.28 ft (1 m) | ||
Power supply | (6) 1.5 V AA alkaline batteries | (8) 1.5 V D cell alkaline batteries | – |
Auto power off | 15 minutes idle | – | – |
Battery life | Approx. 35 hours at 70 °F (21 °C) (Typical) | Approx. 16 hours at 70 °F (21 °C) (Typical) | – |
Overload protection | – | 600 V rms Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm |
– |
Agency approval | |||
Safety compliance | IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 |
IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 IEC 61010-031, CSA/UL 61010-031 (test leads) |
IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 |
Size (H x W x L) | Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm) | Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm) | Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm) |
Weight | Approx. 4.2 lb (1.9 kg) (batteries installed) | Approx. 7.0 lb (3.2 kg) (batteries installed) | Approx. 1.9 lb (0.85 kg) |
Features | UAT-600-R Receiver | UAT-600-T Transmitter | SC-600 Signal Clamp (included with UAT-620, optional for UAT-610) |
Measurement category | CAT IV 600 V | ||
Operating voltage/current | 0 to 600 V | 0 to 600 V, 100 A max. | |
Operating frequency/tracing modes | Active tracing: 33 kHz and 8 kHz Passive tracing: 50/60 Hz and Radio |
Energized circuit Induction mode: 33 kHz Direct connection modes: 8 kHz and 33 kHz Clamp mode: 8 kHz and 33 kHz De-Energized circuit Induction mode: 33 kHz Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi A-Frame: 8 kHz Clamp mode: 8 kHz and 33 kHz |
33 kHz and 8 kHz |
Locating modes | Peak and Null | – | – |
Depth measurement and accuracy | Up to 20 ft 4 in to 10 ft: pm; 3 % 10 ft to 20 ft: pm; 5 % |
– | – |
Display backlight | Automatic | Yes | – |
Audio indication | Increasing closer to the signal | Fast beeps showing the better signal is applied | – |
Transmitting mode power output | – | Max. 3 watts | – |
Output voltage | – | Max. 50 V rms | – |
Output current | – | Max. 250 mA rms, constant current in 5 steps | – |
Signal voltage output (nominal) | – | – | 23 V rms at 8 kHz 30 V rms at 33 kHz |
Mains voltage measurement | – | 0 V to 600 V, 50 Hz to 60 Hz Resolution: 1 V Accuracy: pm; 10% |
– |
Resistance measurement (De-energized circuit) |
– | 0 ohm; to 999 k ohm; Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;) Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;) Accuracy: pm; 10% |
– |
Output hazardous voltage warning | – | ≥ 30 V rms | – |
Mains hazardous voltage warning | – | ≥ 30 V rms | – |
Sensitivity adjustment (gain control) | Yes | – | – |
Sensitivity at 1 m (typical) | Power: 2 mA Radio: 20 μA 8 kHz: 5 μA 33 kHz: 5 μA |
– | – |
Display | 4.3 in, 320 x 240 BW outdoor LCD display with auto backlight | LCD display (LED backlight) 2.4 in x 1.3 in |
– |
Update rate | Instantaneous | Current (mA): 10 ms Voltage (V): 15 ms Resistance ( ohm;): 330 ms |
– |
Operating temperature and humidity | -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH | ||
Storage temperature and humidity | -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH | ||
Operating altitude | < 6561 ft (< 2000 m) | ||
Pollution degree | 2 | ||
Water and dust resistance | IP54 | ||
Drop proof | 3.28 ft (1 m) | ||
Power supply | (6) 1.5 V AA alkaline batteries | (8) 1.5 V D cell alkaline batteries | – |
Auto power off | 15 minutes idle | – | – |
Battery life | Approx. 35 hours at 70 °F (21 °C) (Typical) | Approx. 16 hours at 70 °F (21 °C) (Typical) | – |
Overload protection | – | 600 V rms Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm |
– |
Agency approval | |||
Safety compliance | IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 |
IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 IEC 61010-031, CSA/UL 61010-031 (test leads) |
IEC 61010-1, IEC 61010-2-033 CSA/UL 61010-1, CSA/UL 61010-2-033 |
Size (H x W x L) | Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm) | Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm) | Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm) |
Weight | Approx. 4.2 lb (1.9 kg) (batteries installed) | Approx. 7.0 lb (3.2 kg) (batteries installed) | Approx. 1.9 lb (0.85 kg) |
No reviews