Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
The Amprobe HD110C IP67 Heavy Duty Multimeter is meant for professional use in choking environments. The meter is unusually rugged and obedient in unknown unventilated use applications. It's made using waterproof construction to prevent dirt, grime, and moisture from entering the lawsuit and causing inaccurate readings or damaging shorts.
Built of tough, flame-retardant thermoplastic resistant to grease and chemical spills, gone all sore components wonder-mounted for a slip-resistant to at least eight feet. The HD110C has an outstretched voltage measurement facility of 1500 V DC and 1000 V AC, unmatched by any appendage origin of digital multimeters. The outstretched voltage ranges can withstand transients occurring to 12 kV.
FEATURE | HD110C | HD160C |
DC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V | 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V |
AC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V | 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V |
Current | AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A | 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A |
Resistance | 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO | 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO |
Diode | • | – |
Continuity | • | |
Frequency | – | 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz |
Capacitance | – | 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF |
Temperature | – | -4 °F → 2372 °F (-20 °C → 1300°C) |
True-rms | – | • |
Specifications | |
DC Volts range: | 200 mV, 2 V, 20 V, 200 V, 1500 V |
DC Volts resolution: | 0.1 mV |
DC Volts accuracy: | All ranges ±(0.1 % rdg+2 dgts) |
DC Volts input impedance: | 10 MO |
DC Volts OL protection: | >1500 V DC/1000 V AC rms |
DC Volts transient protection: | >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
AC Volts (45 Hz to 2 kHz) ranges: | 200 mV, 2 V, 20 V, 200 V, 1000 V |
AC Volts (45 Hz to 2 kHz) resolution: | 0.1 mV |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) input impedance: | 10 MO |
AC Volts (45 Hz to 2 kHz) OL protection: | 1500 V DC/1000 V AC rms |
AC Volts (45 Hz to 2 kHz) transient protection: | 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
DC Current range: | 200 µA, 2 mA, 20 mA, 200 mA, 2 A |
DC Current resolution: | 0.1 µA |
DC Current accuracy: | 200 µA to 20 mA ±(0.5 % rdg+2 dgts) |
DC Current accuracy: | 200 mA to 2 A ±(1.0 % rdg+2 dgts) |
No reviews