Fluke 414D Distance Measuring Laser may be a huge boost up from the common measuring system and it's a lot of easier to use. simply purpose and click on. No scales to interpret or misread.
The Fluke 414D measures up to fifty meters (165 foot.), with a pair of a millimeter (0.08 in) accuracy and also the further bright optical maser makes targeting straightforward.
This professional-grade optical maser distance meter is quick and straightforward to use to assist improve accuracy and scale back mensuration errors. you may save time and cash at each step.
So, now you have no doubt about Fluke 414D. Kep the process so simple and get the best product from Fluke Bangladesh.
Distance Measurement | |
Typical measuring tolerance 1 | ±2.0 mm 3 |
Maximum measuring tolerance 2 | ±3.0 mm 3 |
Range At Leica Target Plate GZM26 | 50 m / 165 ft |
Typical range 1 | 40 m / 130 ft |
Range at unfavorable condition 4 | 35 m / 115 ft |
Smallest unit displayed | 1 mm / 1/16 in |
Ø Laser point at distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt Measurement | |
Measuring tolerance to laser beam 5 | No |
Measuring tolerance to housing 5 | No |
Range | No |
General | |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP40 |
Automatic laser off | After 90 seconds |
Automatic power off | After 180 seconds |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
Size (L x W x D) | 116 x 53 x 33 mm |
Weight (with batteries) | 113 g |
Temperature range Storage operation |
-25°C to +70°C (-13°F to +158°F) |
0°C to +40°C (32°F to +104°F) | |
Calibration cycle | Not applicable |
Maximum altitude | 3000 m |
Maximum relative humidity | 85% at 20°F to 120°F (-7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |