Fluke 424D Laser Distance Meter has some great feature that saves you more time in more situations and reduces errors. Fluke laser distance meter not only provide the accurate result but also the value of this Fluke meter always spot on.
Fluke 424D Laser Distance Meter is a rugged, accurate & reliable Laser Distance Meter that you can depend on.
As a Fluke authorized distributor in Bangladesh we Iconic Engineering Limited offer the lowest price Fluke laser distance meter in Bangladesh. We not only a Fluke agent company but also we are the sole distributor of Fluke in Bangladesh.
Distance Measurement | |
Typical measuring tolerance 1 | ±1.0 mm 3 |
Maximum measuring tolerance 2 | ±2.0 mm 3 |
Range At Leica Target Plate GZM26 | 100 m / 330 ft |
Typical range 1 | 80 m / 260 ft |
Range at unfavorable condition 4 | 60 m / 195 ft |
Smallest unit displayed | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Ø Laser point at distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt Measurement | |
Measuring tolerance to laser beam 5 | ±0.2° |
Measuring tolerance to housing 5 | ±0.2° |
Range | 360° |
General | |
Laser cass | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP54 |
Automatic laser off | After 90 seconds |
Automatic power off | After 180 seconds |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 5,000 measurements |
Size (L x W x D) | 127 x 56 x 33 mm |
Weight (with batteries) | 158 g |
Temperature range Storage operation | -25°C to +70°C (-13°F to +158°F) |
-10°C to +50°C (14°F to +122°F) | |
Calibration cycle | Tilt and compass |
Maximum altitude | 3000 m |
Maximum relative humidity | 85% at 20°F to 120°F (-7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |