Fluke 419D Laser Distance Meter you can use this to live up to eighty m (260 foot.), correct to + one millimeter. No scales to interpret or misread. the additional bright optical device makes it straightforward to focus on even at long distances.
Fluke 419D can assist you to save time and scale back errors with increased options like storage for twenty complete displays, indirect mathematician distance calculations, and therefore the stand mode for stable, long-distance measurements. And, you will be ready to see the results a lot of simply on the backlit show.
Despite your job, Fluke 419D optical device distance meter provides correct long-distance measurements to assist you are doing the work of 2 individuals on your own.
We operated Fluke Bangladesh for distributing our Fluke test & measurement tools in Bangladesh. As a Fluke authorized distributor in Bangladesh, we always trying to provide the right tools for the right customer for an accurate and reliable result.
Distance Measurement | |
Typical measuring tolerance 1 | ±1.0 mm 3 |
Maximum measuring tolerance 2 | ±2.0 mm 3 |
Range at Leica Target Plate GZM26 | 80 m / 260 ft |
Typical range 1 | 80 m / 260 ft |
Range at unfavorable condition 4 | 60 m / 195 ft |
Smallest unit displayed | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Ø Laser point at distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt measurement | |
Measuring tolerance to laser beam 5 | No |
Measuring tolerance to housing 5 | No |
Range | No |
General | |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP54 |
Automatic laser off | After 90 seconds |
Automatic power off | After 180 seconds |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 5,000 measurements |
Size (L x W x D) | 127 x 56 x 33 mm |
Weight (with batteries) | 153 g |
Temperature range Storage operation | -25°C to +70°C (-13°F to +158°F) |
-10°C to +50°C (14°F to +122°F) | |
Calibration cycle | Not applicable |
Maximum altitude | 3000 m |
Maximum relative humidity | 85% at 20°F to 120°F (-7°C to 50°C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |