

Fluke 375 True RMS AC/DC Clamp Meter
Branch: Industrial Grade
Category: Clamp Meters
Ave. Rating:
In Stock: 10
Offer Price: ৳ 9,000
Be prepared for all accurate results all the time.
Fluke 375 True RMS AC/DC Clamp Meter comes with a better feature and accuracy. The Fluke 375 clamp meter's most important thing that it always provides an accurate result in any environment.
With True RMS AC voltage and current measurements, the Fluke 375 Clamp Meter will scan up to 600 V and 600 A in each AC and DC modes and can frequency activity up to five hundred cycles per second.
The 375 is compatible with the new iFlex versatile current probe (sold separately), which expands the activity vary to 2500 A AC.
As a Fluke authorized distributor in Bangladesh, we offer top quality clamp meter at the best price.
Features
Features and benefits:
- iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
- CAT IV 600 V, CAT III 1000 V
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Three-year warranty
- True RMS AC voltage and current for accurate measurements on non-linear signals
- 500 mV DC measurement range to interface with other accessories
- Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Soft carrying case
Specifications
Specifications: Fluke 375 True RMS AC/DC Clamp Meter
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
|||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||
376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
|||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
![]() |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1% ± 5 digits | |||
mV dc | ||||
Range | 375 and 376 | 500.0 mV | ||
Resolution | 0.1 mV | |||
Accuracy | 1% ± 5 digits | |||
Frequency via Jaw | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥10 A | |||
10 – 100 Hz, ≥5 A | ||||
100 – 500 Hz, ≥10 A | ||||
Frequency via Flexible Current Probe | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
20 – 100 Hz, ≥ 20 A | ||||
100 – 500 Hz, ≥ 25 A | ||||
Resistance | ||||
Range | 374 375 and 376 |
6000 Ω 60 kΩ |
||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
||
375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
|||
Accuracy | 1% ± 5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
|||
Accuracy | 1% ± 4 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
Weight | 388 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | 10°C – +50°C | |||
Storage Temp | -40°C – +60°C | |||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
|||
Operating Altitude | 3000 meters | |||
Storage Altitude | 12,000 meters | |||
EMC | EN 61326-1:2006 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
|||
Safety Specifications | ||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
|||
Agency Approvals | ||||
Batteries | 2 AA, NEDA 15A, IEC LR6 |
Includes
Models: Fluke 375 True RMS AC/DC Clamp Meter
Includes:
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
Accessories
Accessories: Fluke 375 True RMS AC/DC Clamp Meter
- N/A
Resources

Fluke 368 FC Leakage Current Clamp Meter
Model: Fluke 368 FC Leakage Current Clam...

Fluke 353 True RMS 2000 A Clamp Meter
Model: Fluke 353 True RMS 2000 A Clamp M...

AMP-220 600A AC/DC TRMS Clamp Meter
With a full vary of AC/DC current, AC/DC...

Fluke 302 Plus Clamp Meter
Model: Fluke 302 Plus Clamp Meter Compa...

Fluke 323 True RMS Clamp Meter
Model: Fluke 323 True RMS Clamp Meter F...

Amprobe-220 600A AC/DC TRMS Clamp Meter
With a full vary of AC/DC current, AC/DC...

Amprobe-310 Motor Maintenance HVAC Clamp...
Whether you would like associate amp cla...

Fluke 325 True RMS Clamp Meter
Models: Fluke 325 True RMS Clamp Meter...

Fluke 365 Detachable Jaw True RMS AC/DC...
Model: Fluke 365 Detachable Jaw True RMS...

Fluke 355 True RMS 2000 A Clamp Meter
Model: Fluke 355 True RMS 2000 A Clamp M...