Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians produce an effect more efficiently regarding the subject of the achievement site.
The Fluke 902 FC Clamp Meter, by now than Fluke Connect wireless connectivity, can state HVAC technicians add going on productivity in the pitch. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to accomplish many pungent HVAC system measurements: microamps for psychoanalysis pilot roomy sensors; resistance occurring to 60 k. AC current and AC/DC voltage; capacitance; and response temperature, all along with just one tool. Plus its little form factor makes it easy to hang regarding the subject of to and navigate in tight involve a battlespace.
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A > 1.4 MIN@600 A Add 2% for CF>400 A |
|
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) |
|
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) |
|
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V |
|
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
A wireless Fluke Connect-enabled clamp meter designed specifically for the needs of HVAC technicians
Offers 200 A DC current measurements to behave ember rod
Extends resistance range to pretense thermistors taking place to 60k
Captures flue gas temperature
Measures begin and control motor capacitors
Measures adjustable frequency steer undertaking