Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
The Amprobe HD160C Heavy Duty TRMS Multimeter with Temperature is intended for professional use in snappish environments. It's made using waterproof construction to prevent dirt, grime, and moisture from entering the deed and causing inaccurate readings or damaging shorts.
Built taking into consideration tough, a blaze-retardant thermoplastic that is resistant to grease and chemical spills and once surprise-mounted components that are slip-resistant to at least 8 feet, the Amprobe HD160C is unusually rugged and obedient. It has a lengthy voltage measurement expertise of 1500 V DC and 1000 V AC, unmatched by any accessory extraction of digital multimeters. The outstretched voltage ranges can withstand transients taking place to 12 kV, and it plus proceedings temperature. Amprobe is a sister concern of fluke corporation, Fluke Bangladesh is a distributor of fluke in Bangladesh. So all of the instrument both of them are very trusted and reliable. You may choose any type of Electrical tools that is available at Iconic Engineering.
FEATURE | HD110C | HD160C |
DC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V | 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V |
AC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V | 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V |
Current | AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A | 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A |
Resistance | 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO | 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO |
Diode | • | – |
Continuity | • | |
Frequency | – | 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz |
Capacitance | – | 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF |
Temperature | – | -4 °F → 2372 °F (-20 °C → 1300°C) |
True-rms | – | • |
Specifications | |
DC Volts range: | 200 mV, 2 V, 20 V, 200 V, 1500 V |
DC Volts resolution: | 0.1 mV |
DC Volts accuracy: | All ranges ±(0.1 % rdg+2 dgts) |
DC Volts input impedance: | 10 MO |
DC Volts OL protection: | >1500 V DC/1000 V AC rms |
DC Volts transient protection: | >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
AC Volts (45 Hz to 2 kHz) ranges: | 200 mV, 2 V, 20 V, 200 V, 1000 V |
AC Volts (45 Hz to 2 kHz) resolution: | 0.1 mV |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) input impedance: | 10 MO |
AC Volts (45 Hz to 2 kHz) OL protection: | 1500 V DC/1000 V AC rms |
AC Volts (45 Hz to 2 kHz) transient protection: | 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
DC Current range: | 200 µA, 2 mA, 20 mA, 200 mA, 2 A |
DC Current resolution: | 0.1 µA |
DC Current accuracy: | 200 µA to 20 mA ±(0.5 % rdg+2 dgts) |
DC Current accuracy: | 200 mA to 2 A ±(1.0 % rdg+2 dgts) |