Receive in amaizing time
Return policy that lets you shop at ease
We only sell 100% authentic products
Your data is always protected
Withstands drops up to 4-meters (13 feet) with industrial-strength casing and holster. Waterproof, dustproof IP67 case for the most extreme work sites. The Fluke 87V MAX True-RMS Digital Multimeter defines an option all right for dynamic in extreme conditions, when the features and authenticity to troubleshoot most electrical problems.
The 87V MAX has an IP 67 (waterproof and dustproof) rating, the outstretched operational temperature range of -15C to +55C (5F to 131F, -40C for happening to 20 minutes), and 95 % humidity, and has been expected and tested to withstand a 4 m (13 ft) slip.
The Fluke 87V MAX Truerms Digital Multimeter is built to the con in the toughest environments you might point of view. The 87V MAX has an industrial-strength outer shell and a removable holster that doubles as an exam as well as storage and an exam consider holder for one-handed operation.
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
|
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
|
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS |
Min/Max/Avg | Yes | |
Reading hold/Auto (Touch) Hold | Yes | |
Relative reference | Yes | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph | 32 segments, updates 40/second | |
Backlight | Two level | |
Low pass filter (VFD measurements) | Yes | |
Input Alert™ | Yes | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
|
Agency approvals | CE, CSA | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67 | |
Power | Three AA batteries. 800 hours typical, without backlight | |
Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
Weight | 698.5 g (with holster) | |
Warranty | Limited lifetime | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
Storage temperature | -40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
|
Operating altitude | 2000 m |
No reviews