Versatile and Fluke 353 True RMS 2000 A Clamp Meter with high currents Confidently take reliable readings with actuality RMS, Fluke 353 digital clamp meter; the tools of selection for prime current clamp-on amp meter activity up to 2000 A. The extra-wide jaw simply clamps around massive conductors, usually found in high-current applications. The extra-rugged style and CAT IV 600 V, CAT III a thousand V ratings add an additional component of user protection once taking high-powered measurements.
Accurate peak measurements will be taken into the exploitation of the in-rush current mode, ideal for motors and inductive hundreds. One of the most important things about Fluke 353 clamp meter not only provide you the accurate result but also the value of this meter top of the line.
Fluke Bangladesh provides a wide range of Fluke test and measurement tools in Bangladesh. Fluke BD owned and operated by us. Iconic Engineering Limited the sole distributor of Fluke. We offer the lowest price Fluke 353 Clamp Meter in Bangladesh.
Electrical Specifications | ||||
Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC RMS | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC RMS | ||
Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|||
Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC RMS | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | ||
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |||
Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |||
Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |||
Trigger level | Refer to current and voltage tables | |||
1. Add 2% to error spec for CF > 2 | ||||
General Specifications | ||||
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | |||
Battery life (with typical usage, backlight off) | 100 hours | |||
Test leads | Rated to 1000 V | |||
Weight | .814 kg (1.8 lb) | |||
Jaw size | 58 mm (2.28 in) | |||
Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | |||
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |||
Environmental Specifications | ||||
Operating temperature | 32°F to +122°F (0°C to +50°C) | |||
Storage temperature | -4°F to 140°F (-20°C to +60°C) | |||
Operating humidity | 0 to 95% (non-condensing) | |||
Operating altitude | 2000 m | |||
Storage altitude | 10,000 m | |||
IP rating | 42 (indoor use only) | |||
Drop test requirements | 1 m | |||
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
|||
Temperature coefficients | Current | 0.1% of reading per °C outside 22°C to 24°C | ||
Voltage | 0.1% of reading per °C outside 22°C to 24°C |