Fluke 319 Clamp Meter the best tool for an accurate result. The most important things about this meter very easy to use.
The Fluke 319 is meant also than ergonomic concepts, shaped to fit your hand and to admission tight spots easily.
These little and rugged clamp meters are ideally suited for current measurements occurring to 1000 A (319) in tight cable compartments. The Fluke 319 plus have enough maintenance AC/DC current measurements and has a well ahead unqualified for colossal quantity below 40 A.
In adjoining to a compact package bearing in mind than a mighty feature set, the Fluke 319 with equipping subsequent to In-hurry current and Frequency functions for psychiatry motors, lighting, etc.
General specifications | |
Digital display | 6000 count resolution |
Low battery Indication | Displays a signal when the batteries are below their required voltage |
Power source | Three AAA IEC LR03 batteries |
Clamp opening size | 1.45 in (37 mm) |
Jaw diameter | 1.45 in (37 mm) |
Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in |
(162.4 x 58.25 x 30.5 mm) | |
Weight | Approximately 13.5 oz (384 g) (batteries included) |
Auto range | Available in Ohms |
Safety | CE |
EN/IEC 61010-1 and IEC 61010-2-032 | |
Measurement Category: 600V CAT III |
317 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600 A} | ||
2.5% ±5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
319 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600/1000 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω |
4000 Ω | ||
Resolution | 0.1 Ω | |
1 Ω | ||
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | 100 ms |
Frequency | Range | 5.0 - 500.0 Hz |
Accuracy | 0.5% ±5 digit | |
Trigger Level | 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A | |
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
Environmental specifications | |
Operating temperature | 14°F to 122°F (-10 °C to 50 °C) |
Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
Operating humidity | Non-condensing (< 50 °F) (< 10 °C) |
90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |
75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |
45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |
(Without condensation) | |
Operating altitude | 1 mile (2000 meters) above mean sea level |
Storage altitude | 7 miles (12,000 meters) above mean sea level |
IP Rating | IP40 |
Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor |
EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m |
Temperature coefficients | 0.1x (specified accuracy)/ °C |
(<64 °F or > 82° F) | |
(<18 °C or > 28 °C) |