Fluke 1587 FC Insulation Multimeter

Fluke 1587 FC Insulation Multimeter

Good
Out of Stock
Brand:Fluke
Branch: Industrial Grade

Fast Delivery

Receive in amaizing time

Easy Return

Return policy that lets you shop at ease

Always Authentic Products

We only sell 100% authentic products

Secure Shopping

Your data is always protected

Overview
Specifications
Features
Resources
Reviews

With the Fluke 1587 FC Insulation Multimeter Keep yourself safe. Find hidden problems faster. Put the paperwork down. Very easy to use and always provide accurate result in any environment. 

We Fluke Bangladesh offer the reliable & lowest price Fluke 1587 FC Insulation Multimeter in Bangladesh. The most important things about the fluke 1587 FC Insulation Multimeter that not only a reliable product but also the value of this brand new Fluke product always spot on.

Specification: Fluke 1587 FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance  10 MΩ (nominal), <100 pF
Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA 
Resolution 0.01 mA 
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection  1000 V rms or dc
Open circuit test voltage  <8.0 V dc
Short circuit current  <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz  0.01 Hz  ±(0.1% + 1)
999.9 Hz  0.1 Hz  ±(0.1% + 1)
9.999 kHz  0.001 kHz  ±(0.1% + 1)
99.99 kHz  0.01 kHz  ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 mV 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV 
DC Trigger Levels¹ to 20 kHz² NA
6.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  1.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V 
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  10.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V 
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  300.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range  Resolution  Accuracy ±(% of Rdg+Counts)
1000 nF  1 nF ±(1.2% + 2)
10.00 μF  0.01 μF ±(1.2% + 2)
100.0 μF  0.1 μF ±(1.2% ±90 counts)
9999 μF  1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range  Resolution  Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts)
-40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ 
Resolution 100 MΩ 
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility 
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries  Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

Model: Fluke 1587 FC Insulation Multimeter

Key Features:

  • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.
  • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely.
  • Quickly find problems by saving and comparing measurements over time on a wireless device.
Leave a review

Reviews

No reviews

Trending Items

Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Fluke 1507 Insulation Resistance Tester

Fluke 1507 Insulation Resistance Tester

Good
Fluke 1587 FC Insulation Multimeter

Fluke 1587 FC Insulation Multimeter

Good
Fluke 1503 Insulation Resistance Meter

Fluke 1503 Insulation Resistance Meter

Good
Fluke 1555 FC 10 kV Insulation Tester

Fluke 1555 FC 10 kV Insulation Tester

Good