7526A Precision Process Calibrator

7526A Precision Process Calibrator

Good
Out of Stock
Brand:Fluke
Branch: Industrial Grade

Fast Delivery

Receive in amaizing time

Easy Return

Return policy that lets you shop at ease

Always Authentic Products

We only sell 100% authentic products

Secure Shopping

Your data is always protected

Overview
Specifications
Features
Reviews

Doing more with less” is a requirement every process manufacturer faces today. To maintain product quality, reduce waste, improve efficiency and conform to regulatory standards, instruments that measure process variables such as temperature and pressure must be calibrated at regular intervals.

Selecting the right calibrator for the job, however, can be tricky—especially when attempting to balance precision and versatility with the cost. Less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators, the 7526A is a “best fit” for instrument shops that value precision, versatility and economy.

Specifications: 7526A Precision Process Calibrator

DC voltage, output
Range [1] Absolute Uncertainty, ±
(ppm of output + μV), 1-yr
Resolution
0 to 100 mV 30 3 1 μV
0 to 1 V 30 10 10 μV
0 to 10 V 30 100 100 μV
0 to 100 V 30 1 mV 1 mV
TC Output and Input
–10 mV to 75 mV 30 2 μV 1 μV

[1] All outputs are positive only unless otherwise noted

DC voltage, isolated input
Range Absolute Uncertainty, ±
(ppm of reading + mV),
1-yr
Resolution
0 to 10 V 100 0.2 100 μV
10 V to 100 V 100 2.0 1 mV
DC Current, output
Range[1] Absolute Uncertainty,
± (ppm of reading + μA),
1-yr
Resolution
0 to 100 mA 50 1 1 μA

[1] For line voltages less than 95 V, ±100 ppm of reading

DC current, isolated input
Range Absolute Uncertainty, ±
(ppm of reading + μA),
1-yr
Resolution
0 mA to 50 mA 100 1 0.1 μA
0 mA to 24 mA [1][2]
(Loop Power)
100 1 0.1 μA

[1] Loop Power: 24 V ±10%
[2] HART Resistor: 250 Ω ± 3%

Resistance, output
Range Absolute
Uncertainty,
tcal ± 5 °C, ±
Ohms, 1-yr
Resolution Nominal
current
5 Ω to 400 Ω 0.015 0.001 Ω 1 to 3 mA
5 Ω to 4 kΩ 0.3 0.01 Ω 100 μA to 1 mA
Resistance, input
Range Absolute Uncertainty, ±
(ppm of reading + Ω), 1-yr
Resolution
0 Ω to 400 Ω 20 0.004 0.001 Ω
0 Ω to 4 kΩ 20 0.04 0.01 Ω
Sample thermocouple accuracy, input/output
(does not include all available TC types)[1]
TC type Temperature Range (°C) Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr [2]
Min Max
J -210 1200 0.09
K -250 1372 0.1
S -50 1767 0.29
T -250 400 0.11

[1] See extended specifications for all TC types (B,C,E,J,K,L,N,R,S,T,U,XK,BP)
[2] Best accuracy within specified TC temperature range

Sample RTD and thermistor, output
(does not include all available RTD types)[1]
RTD Type Temperature Range (°C) Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr
Min Max
Pt 385, 100 Ω -200 800 0.05
YSI 400 15 50 0.007

[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

Sample RTD and thermistor, intput
(does not include all available RTD types)[1]
RTD Type Temperature Range (°C) Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr
Min Max
Pt 385, 100 Ω –80 100 0.020
100 300 0.024
300 800 0.038
YSI 400 15 50 0.007

[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

General specifications
Standard interface RS-232, IEEE-488 (GPIB)
Temperature
performance
Operating: 0 °C to 50 °C
Calibration (tcal): 18 °C to 28 °C
Storage: –20 °C to 70 °C
Electromagnetic
compatibility
CE: Conforms to EN61326;
operation in controlled EM environments
Temperature coefficient Temperature coefficient for temperatures
outside tcal 5 °C is 10% of the 90-day
specification (or 1 year if applicable) per °C
Relative humidity Operating: <80% to 30 °C
<70% to 40 °C
<40% to 50 °C
Altitude Operating: 3,000 m (9,800 ft) max
Non-operating: 12,200 m (40,000 ft) max
Safety EN/IEC 
61010-1:2010 3
rd Edition,
UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12
Analog low isolation 20 V
Line power 120 V~: 100 V to 120 V
240 V~: 220 V to 240 V
Line frequency 47 Hz to 63 Hz
Line voltage variation ± 10 % about setting
Power consumption 15 VA maximum
Dimensions Height: 14.6 cm (5.75 in)
Width: 44.5 cm (17.5 in)
Depth: 29.8 cm (11.75 in)
Weight
(without options)
4.24 kg (9.35 lb)

Key Features: 7526A Precision Process Calibrator

  • Sources and measures dc voltage, current, resistance, RTDs and thermocouples
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Includes 24 V dc transmitter loop power supply
  • Measures 4-20 mA loop current
  • Includes automated switch-test function
  • Accepts ITS-90 coefficients for accurate SPRT measurements
  • Compatible with MET/CAL® Calibration Software
  • Includes certificate of calibration traceable to national standards (optional A2LA accredited calibration available upon request)
Leave a review

Reviews

No reviews

Trending Items

Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Fluke 718 Pressure Calibrator

Fluke 718 Pressure Calibrator

Good
Fluke 729 Automatic Pressure Calibrator

Fluke 729 Automatic Pressure Calibrator

Good
7526A Precision Process Calibrator

7526A Precision Process Calibrator

Good
Fluke 700G Pressure Gauge Calibrator

Fluke 700G Pressure Gauge Calibrator

Good