Fluke RSE300 Mounted Infrared Camera
introducing the first-ever fully-radiometric, mounted Fluke infrared cameras – the RSE series. Equipped with advanced features and software plug-ins to MATLAB® and LabVIEW®, these tools are ideal for continuously streaming and analyzing infrared data.
Key Features | |
IFOV with standard lens (spatial resolution) | 1.85 mRad |
Detector resolution | 320 x 240 (76,800 pixels) |
Field of view | 24 °H x 18 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
Camera focus options | Focus is adjusted in SmartView® desktop software |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
IR-Fusion® technology | Yes, in SmartView® desktop software. Five modes of image blending (AutoBlend™ mode, Picture-in-Picture (PIP), IR/Visible alarm, Full IR, Full visible light) add the context of the visible details to your infrared image |
Thermal sensitivity (NETD) | ≤ 0.040 °C at 30 °C target temp (40 mK)* |
Filter mode (NETD improvement) | Yes |
Level and span | Smooth auto and manual scaling, in SmartView® desktop software |
Fast auto toggle between manual and auto modes | Yes, in SmartView® desktop software |
Fast auto-rescale in manual mode | Yes, in SmartView® desktop software |
Minimum span (in manual mode) | 0.1 °C (0.18 °F), in SmartView® desktop software |
Minimum span (in auto mode) | <1.0 °C (<1.8 °F), in SmartView® desktop software |
Built-in digital camera (visible light) | 5 megapixel industrial performance |
Frame rate | 60 Hz or 9 Hz versions |
Digital zoom | Variable up to 16x in SmartView® desktop software |
*Best possible |
Data storage and image capture | |
Memory options | Connect to SmartView® desktop software for storage to device or upload to Fluke Cloud™ for permanent storage Capture, save and analyze images in SmartView® desktop software |
Image capture, review, save mechanism Image file formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Software | SmartView® desktop software—full analysis and reporting software Compatible with MATLAB® and LabVIEW® software |
Export file formats with SmartView® desktop software | Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
Voice annotation | Yes, in SmartView® desktop software |
Text annotation | Yes, in SmartView® desktop software |
Video recording | Yes, in SmartView® desktop software |
File formats video | Non-radiometric (MPEG-encoded .AVI) and fully-radiometric (.IS3), in SmartView® software |
Remote display viewing | Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® desktop software on a PC; via WiFi hotspot to the Fluke Connect® app |
Remote control operation | Yes, through ethernet or SmartView® desktop software |
Temperature measurement | |
Temperature measurement range (not calibrated below -10 °C) | -10 °C to +1200 °C (14 °F to +2192 °F) |
Accuracy | ± 2 °C or ± 2 %, whichever is greater |
Reflected background temperature compensation | Yes, in SmartView® desktop software |
Transmission correction | Yes, in SmartView® desktop software |
Live line marker | Yes, in SmartView® desktop software |
Color Palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General specifications | |
Color alarms (temperature alarms) | Yes, in SmartView® desktop software–high temperature, low temperature, and isotherms (within range) |
Infrared spectral band | 8 μm to 14 μm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Center-Point temperature measurement | Yes, in SmartView® desktop software |
Spot temperature | Yes, in SmartView® desktop software–hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers, in desktop software |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp display, in desktop software |
Electromagnetic compatibility | EN 61326-1:2013 IEC 61326-1:2013; (Industrial) |
US FCC | CFR 47, Part 15 Subpart B Class A |
Vibration | IEC 60068-2-26 (sinusoidal vibration): 3G, 11–200 Hz, 3 axis |
Shock | IEC 60068-2-27 (mechanical shock): 50G, 6 ms, 3 axis |
Size (H x W x L) | 8.3 x 8.3 x 16.5 cm (3.3 x 3.3 x 6.5 in) |
Weight (battery not included) | 1 kg (2.2 lb) |
Enclosure rating | IEC 60529: IP67 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |