Fluke 373 True-RMS AC Clamp Meter easily can measures resistance to 6000 Ω with continuity detection.
Fluke 373 True-RMS AC Clamp Meter is an earsplitting substitute for AC-unaccompanied current measurement situations. Featuring True RMS AC voltage and current measurements you can undertaking AC current to 600 A and AC voltage to 600V. The 373 along with events DC voltage to 600 V and resistance to 6000.
To make it even easier to use, the large, easy-to-right of admission backlit display provides greater than before visibility in dimly lit conditions.
And the 373 automatically sets the truthful measurement range based very about the voltage function along with in the middle of your to power going on, so you get your hands on not need to impinge on the switch even if taking a measurement. When you put it all together, you'll locate the Fluke 373 offers anything you need, benefit a tiny more.
Fluke tools always provide an accurate result in any environment. The wide range of Fluke clamp meter like as Fluke 381, Fluke 375, Fluke 368 FC also provide the best result that you are looking for.
Electrical Specifications | |
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (48 – 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 @ 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0 % ± 5 digits (48 – 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1 % ± 5 digits |
Resistance | |
Range | 600.0 Ω/6000 Ω |
Resolution | 0.1 Ω/1 Ω |
Accuracy | 1 % ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 – 100.0 μF / 1000 μF |
Resolution | 0.1 μF/1 μF |
Accuracy | 1.9 % ± 2 digits |
Mechanical Specifications | |
Size (L x W x H) | 232 mm x 85 mm x 45 mm |
Weight | 370 g |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temp | -40 °C to +60 °C |
Operating Humidity | Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
Agency Approvals | |
Batteries | 2 AA, NEDA 15A, IEC LR6 |